Specifications |
Other Information |
1. User Control Panel 2. Carrying Handle 3. No-Draft Diffuser 4. Cleanroom-Grade HyperHEPA Filter
5. Snap-Open Locking Arms 6. High-Performance Centrifugal Fan 7. Advanced Fan Control 8. Pre-Max Pre-Filter (Class F9) 9. Dual Floor Air Intake |
Professional Control Airborne Particulates
The IQAir® Cleanroom Series has been designed specifically for the removal of airborne particles. The systems
feature the highest air delivery and longest filter life of any IQAir particle filter system. To allow for maximum air delivery the systems contain no gas phase filtration. The Cleanroom Series
provides a choice of 2 models ( H11 and H13
), each with a specific filter efficiency and air delivery profile. While healthcare facilities may require higher air
delivery to achieve optimum control of microorganisms (e.g. in ICUs or TB isolation rooms), a cleanroom facility may need a filtration efficiency of 99.97% to meet strict manufacturing
regulations or standards.Positive and Negative Pressure Environments Each IQAir® Cleanroom system can be used as a recirculation device or it can be combined with IQAir's ducting
adapters InFlow W125 or OutFlow W125 to create positive and negative pressure environments. The creation of negative pressure helps to contain harmful particles, such as microorganisms, in a
particular area (e.g. TB isolation). The creation of positive pressure helps to protect clean areas from contaminants entering from adjacent rooms (e.g. protective isolation of
immuno-compromised patients, controlled environments for medical device manufacturing). Decentralised Airborne Infection Control in Health-Care Facilities Airborne pathogens in
health-care environments pose a particular risk to immunocompromised patients who may inhale fungal spores, bacteria and viruses. Airborne microorganisms can not only complicate recovery from
surgery, but can also lead to life-threatening infections,costing health-care services hundreds of millions every year. Hospital-acquired aspergillosis for example has been recognised
increasingly as a cause of severe illness and high mortality in immunocompromised individuals, e.g. patients undergoing chemotherapy and/or organ or bone marrow transplants. In the light of the
marked increase in nosocomial infections over recent years, many of which are caused by drug-resistant pathogens, the importance of using high-efficiency air filtration systems beyond the
confines of so-called "critical areas" (such as operation theatres) has once again been emphasised. Both the World Health Organisation (WHO) and the Centers for Disease Control and Prevention
(CDC), advise that, wherever possible, preventive infection control measures should be implemented to reduce the risk of nosocomial infections.
read full report For more critical control of gaseous compounds see our GC AM
, GC Chemisorber
, GC MultiGas
, or GC VOC
models. Also see our GCX AM
, GCX Chemisorber
, GCX MultiGas
, or GCX VOC
models. |
General |
Number of Selectable Fan Speeds |
5 |
Air Delivery (with new filters installed) per Speed |
1 - 45 cfm 2 - 70 cfm 3 - 90 cfm 4 - 155 cfm 5 - 270 cfm
|
Maximum Coverage Area |
1200 sq ft (based on maximum fan speed and an 8.5 ft ceiling) |
System Efficiency for Particles |
99.997% or more at 0.3 µm |
Power Requirements |
115 VAC 50-60 Hz The entire electrical system is UL certified. |
Energy Consumption (Max) |
195 W |
Standby Energy Consumption |
2.5 W |
Power Cable |
Grounded Detachable 10 foot |
Dimensions |
H 32" W 15" D 16" |
Net Weight (including filters) |
33 lbs |
Warranty Period |
1 yr on unit including fan motor, excluding filters |
Filters |
Number of Filter Stages |
2 (fine dust & micro dust filtration) |
Total Number of Replacement Filters |
2 (pre-filter, HEPA Filter) |
Pre-Filter |
32 sq ft mini-pleat fine dust filter |
HEPA Filter Efficiency |
99.97% at .3 microns |
HEPA Filter Surface Area |
44 sq ft. |
Filter Frame Material |
Expanded polystyrene (EPS), chlorofluorocarbon (CFC) - free |
Filter Life |
Pre-Filter 6-18 months HEPA up to 2 years (filter life is dependant
on the operating environment) |
Housing |
Number of Housing Modules |
6 |
Housing Material |
PC-ABS and ABS(UV-stabilized) |
Color of Main Housing/Arms |
Light Gray/White |
Air Intake |
Two side openings at base of unit |
Air Outlet |
Via diffuser with horizontal 320 degree opening on top of unit |
Fan |
Fan Type |
Centrifugal fan, backward curved, single inlet |
Bearings |
Maintenance-free steal ball bearings |
Speed Regulation |
Voltage reductions via capacitor switching |
Electronic Control Panel
|
Control Panel Finish |
Polyester overlay panel |
Main Display |
Liquid crystal display, 16 character x 2 line |
Status and Indicator LEDs |
Timer Status LED, Filter Life Status LEDs, Fan Speed Indicator LEDs
|
Display Languages |
English, French, German, Italian, Spanish |